Who this guideline covers
Patients receiving mechanical ventilation, including invasive and noninvasive support where specified
Read the original guidelineKey recommendations
AARC used GRADE. The literature review included all age groups. Apply each recommendation to the patient and interface it addresses, using population-specific targets where relevant.
Check plateau pressure and tidal volume
AARC recommends checking plateau pressure and assessing and documenting tidal volume by predicted body weight as part of lung-protective ventilation.
Strong · high certainty
Assess PEEP and auto-PEEP
Record the set PEEP and assess for intrinsic PEEP where a valid measurement is feasible. Incomplete exhalation can raise total PEEP above the set value.
Strong · high certainty
Use driving pressure as additional context
AARC suggests assessing driving pressure. Interpret the difference between plateau pressure and total PEEP in the context of valid measurements, patient effort, and the clinical course.
Conditional · low certainty
Assess oxygen delivery and humidification
Review FiO₂ in relation to oxygenation. Assess humidification adequacy during invasive or noninvasive ventilation. AARC also suggests checking whether the humidification device used for NIV is appropriate.
Conditional · very low certainty for FiO₂ and humidification adequacy · low certainty for NIV device choice
Inspect the interface, airway, and cuff
Inspect skin around artificial airways and NIV interfaces and use a manometer when assessing cuff pressure. AARC also suggests evaluating dressings and checking artificial-airway placement and securement.
Skin and manometer assessment strong / high · dressings and securement conditional / low
Account for the limits of remote assessment
AARC suggests direct bedside assessment when resources permit. In resource-limited settings, telemonitoring can supplement the assessment.
Conditional · low certainty
Evidence ratings refer to the original AARC guideline.
Clinical context
An assessment recommendation tells you what to measure
An individual ventilator target depends on the patient and the condition being treated. The ATS ARDS guideline provides disease-specific tidal volume and plateau-pressure targets for adults with ARDS.
The measurement conditions matter
Check whether a plateau reading reflects a valid inspiratory hold and whether total PEEP was measured under appropriate conditions. Patient effort or a leak can make a displayed value hard to interpret. The static compliance calculator explains both measurements and how they enter the calculation.
Practice case
A passive, ventilated adult has a plateau pressure of 26 cm H₂O, set PEEP of 5 cm H₂O, and measured total PEEP of 10 cm H₂O.
What is the calculated driving pressure?
Show the reasoning
The calculated driving pressure is 16 cm H₂O (26 minus 10), assuming the holds were valid. Using the set PEEP would give 21 cm H₂O and would miss the contribution of intrinsic PEEP.
Related PulmTools resources
References
- AARC Clinical Practice Guideline: Patient-Ventilator Assessment
Goodfellow LT, Miller AG, Varekojis SM, LaVita CJ, Glogowski JT, Hess DR. Respir Care. 2024;69(8):1042–1054. doi:10.4187/respcare.12007.
Primary source for the assessment recommendations, GRADE ratings, and four clinical questions.
- ATS guideline update on management of adult ARDS
Qadir N, Sahetya S, Munshi L, et al. Am J Respir Crit Care Med. 2024;209(1):24–36. doi:10.1164/rccm.202311-2011ST.
Disease-specific context for lung-protective ventilation targets in adults with ARDS.
For education. Use patient-specific assessment, the full guideline, and local protocols for bedside decisions.