Pediatric ROX Index Calculator

Calculate age-adjusted ROX-M and the SpO₂/FiO₂ ratio for children on high-flow nasal cannula (HFNC). See the median respiratory rate used in each result.

HFNC measurements

Record SpO₂, set FiO₂, and breathing frequency together while support settings are stable.

ROX-M age range is 1 month to under 18 years.

Enter 94 for 94%.

Enter 40 for FiO₂ 0.40.

Use a rate measured at the same time as SpO₂.

Calculated values

S/F ratio
—
ROX-M
—
Median respiratory rate used
—

How ROX-M is calculated

  • S/F ratio = SpO₂ as a percentage ÷ FiO₂ as a fraction
  • ROX-M = S/F ÷ (measured respiratory rate ÷ age-band median respiratory rate)

For example, SpO₂ of 94% at FiO₂ 0.40 gives an S/F ratio of 235. At 6 months, the Fleming reference band has a median of 39 breaths/min. At a measured rate of 60 breaths/min, ROX-M is 152.75.

How to interpret pediatric ROX-M

How does ROX-M differ from the standard ROX index?

Standard ROX divides S/F by the measured respiratory rate. ROX-M divides S/F by the measured rate relative to the median for the child’s age. PulmTools uses Fleming’s published age-band medians, the 50th centiles of a healthy reference population.

Is there a normal pediatric ROX-M score?

Pediatric ROX-M has no universal normal range or escalation cutoff. In a single-center study of 152 pediatric HFNC cases, ROX-M at 3 hours helped identify children who developed hypoxemic respiratory failure. Kim and colleagues analyzed failure from other causes separately. The adult ROX threshold of 4.88 comes from a different formula and population.

Read ROX-M alongside the S/F ratio, work of breathing, and ventilation. A drop in respiratory rate can make ROX-M rise while S/F stays low. PALICC-2 uses S/F with other criteria when assessing for pediatric ARDS.

Sources